Detail HANNA HI-96710 PH Meter Total Clhorine

The HI96710 portable photometer is for the measurement of pH, free chlorine, and total chlorine. Hanna's portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

 

Features at-a-glance

 

CAL Check™ - Allows for performance verification and calibration of the meter using NIST traceable standards.

 

GLP - Review of the last calibration date.

 

Auto-shut off - Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally left on.

 

Battery status indicator - Indicates the amount of battery life left.

 

Built-in timer - Display of time remaining before a measurement is taken. Ensures that all readings are taken at the appropriate reaction intervals for the test being performed.

 

Error messages - Messages on display alerting to problems including no cap, high zero, and standard too low.

 

Cooling lamp indicator - To maintain the desirable wavelength to be used for absorbance, it is necessary to ensure components are not overheated from the heat generated by the tungsten lamp. Each photometer is designed to allow a minimal amount of time for components to cool. The cooling lamp indicator is displayed prior to a reading being taken.

 

Units of measure - Appropriate unit of measure is displayed along with reading.

 

Specifications

Range pH (P1): 6.5 to 8.5 pH; Free & Total Chlorine (P2 & P3): 0.00 to 5.00 mg/L (ppm)
Resolution pH (P1): 0.1 pH; Free & Total Chlorine (P2 & P3): 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
Accuracy @ 25°C (77°F) pH (P1): ±0.1 pH; Free & Total Chlorine (P2 & P3): ±0.03 mg/L (ppm) ±3% of reading
Light Source : tungsten lamp
Light Detector : silicon photocell with narrow band interference filter @ 525 nm
Method pH (P1): phenol red method; Free & Total Chlorine (P2 & P3): adaptation of the USEPA method 330.5
Auto-off : after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment :  0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery : Type 9V battery
Dimensions : 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Weight : 360g (12.7oz.)
Ordering Information :  HI96710 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual. 

= = = = = = = = = = = = = = = = = = = = =